The ambient temperature sensor is installed in front of the condenser. It detects the ambient temperature to control air conditioning AUTO mode.
This sensor is connected to the A/C amplifier and detects fluctuations in the ambient temperature. This data is used for controlling the cabin
temperature. The sensor sends a signal to the A/C amplifier. The resistance of the ambient temperature sensor changes in accordance with the
ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The A/C amplifier applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature
sensor changes.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. READ VALUE USING TECHSTREAM
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Check the value(s) by referring to the table below.
Air Conditioner
OK:
The display is as specified in the Normal Condition column.
Result:
C -- REPLACE A/C AMPLIFIER
B -- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE See: Heating and Air
Conditioning/Testing and Inspection/Symptom Related Diagnostic Procedures
A -- Continue to next step.
2. INSPECT AMBIENT TEMPERATURE SENSOR
No comments: