Conditioning/Testing and Inspection/Symptom Related Diagnostic Procedures
A -- Continue to next step.
2. INSPECT ROOM TEMPERATURE SENSOR
(a) Remove the room temperature sensor.
(b) Disconnect the room temperature sensor connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NOTICE:
* Hold the sensor only by its connector. Touching the sensor may change the resistance value.
* When measuring, the sensor temperature must be the same as the ambient temperature.
HINT
As the temperature increases, the resistance decreases (see the graph).
Text in Illustration
NG -- REPLACE ROOM TEMPERATURE SENSOR
OK -- Continue to next step.
3. CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - A/C AMPLIFIER)
(a) Disconnect the A/C amplifier connector.