(a) Remove the camshaft timing oil control valve assembly for exhaust camshaft.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
(c) Connect the positive (+) battery terminal to terminal 1 and connect the negative (-) battery terminal to terminal 2. Check the valve
operation.
OK:
Valve moves quickly.
(d) Reinstall the camshaft timing oil control valve assembly for exhaust camshaft.
NG -- REPLACE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (FOR EXHAUST CAMSHAFT) See:
Engine, Cooling and Exhaust/Engine/Actuators and Solenoids - Engine/Variable Valve Timing Actuator/Service and Repair/Removal
OK -- Continue to next step.
3. INSPECT OIL CONTROL VALVE FILTER AND OIL PIPE
(a) Remove the No. 1 oil pipe or No. 2 oil pipe.
(b) Remove the oil control valve filter RH or oil control valve filter LH.
(c) Check that the oil control valve filter and oil pipe are not clogged.