NOTICE:
Do not drop the height control sensor. If it is dropped, replace it with a new one.
(2) Connect 3 1.5 V dry cell batteries in series.
(3) Connect a positive (+) lead from the battery to terminal 3 (SHB) of the height control sensor and a negative (-) lead to terminal 1
(SHG). While applying 4.5 V, slowly moving the sensor's link up and down, and measure the voltage between terminal 2 (SHRR*1
or SHRL*2) and terminal 1 (SHG).
HINT
*1: for RH
*2: for LH
Standard voltage:
for RH
for LH
Text in Illustration
NOTICE:
Do not apply a voltage of more than 6 V.
Result:
E -- REPLACE HEIGHT CONTROL SENSOR REAR LH