Wednesday, November 6, 2019

2019 Cadillac Truck Escalade AWD V8-6.2L Diagnostic Instructions Page 215


* The system voltage is 9-16 volts.



* Power open or close function is initiated.



Conditions for Setting the DTC



B396A 01



The LGM detects a short to voltage in the liftgate motor control circuits.



B396A 02



A loss of B+ voltage to the LGM or the LGM detects a short to ground in the liftgate motor control circuits.



B396A 04



The LGM detects an open/high resistance in the liftgate motor control circuits.



Action Taken When the DTC Sets



Power liftgate operation will be suspended.



Conditions for Clearing the DTC



* The DTC will be current for as long as the fault is present.



* When the fault is no longer present, the DTC will be a history DTC.



* A history DTC will clear after 50 ignition cycles.



Diagnostic Aids



Important: Before testing can be performed the liftgate must be opened. Refer to Opening the Liftgate Without Electrical Power (See:



Body and Frame/Doors, Hood and Trunk/Trunk / Liftgate/Service and Repair/Procedures) for the appropriate procedure.



Whenever the LGM loses power or is disconnected, the ignition must be cycled OFF then ON in order to reactivate the LGM.



In some circumstances high or low control circuit faults may cause the LGM to react as if the liftgate has encountered an object in its travel and



reverse direction.



Reference Information



Schematic Reference



Liftgate Schematics (See: Body and Frame/Doors, Hood and Trunk/Trunk / Liftgate/Diagrams/Electrical Diagrams)



Connector End View Reference



Component Connector End Views (See: Diagrams/Connector Views)



Description and Operation



Liftgate Description and Operation (See: Body and Frame/Doors, Hood and Trunk/Trunk / Liftgate/Description and Operation)



Electrical Information Reference



* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit



Testing/Circuit Testing)



* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic



Procedures/Connector Repairs/Connector Repairs)



* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General



Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)



* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring



Repairs/Wiring Repairs)



Scan Tool Reference



Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information



Circuit/System Verification



1. Ignition ON, doors unlocked, transaxle in Park, enable the power liftgate by pressing the liftgate enable/disable button on the I/P switch



assembly.



2. Open the liftgate by pressing the touchpad on the liftgate handle switch. The liftgate should release and power open.



3. Close the liftgate by pressing the liftgate button switch. The liftgate should power close, cinch-in, and latch.

No comments:

Post a Comment