- The ECM illuminates the MIL and sets a DTC when either one of the following conditions, which could cause emission deterioration, is
detected (2 trip detection logic).
- Within the first 1000 crankshaft revolutions of the engine starting, an excessive misfiring rate (approximately 20 to 50 misfires per 1000
crankshaft revolutions) occurs once.
- After the first 1000 crankshaft revolutions, an excessive misfiring rate (approximately 20 to 60 misfires per 1000 crankshaft revolutions)
occurs 4 times in sequential crankshaft revolutions.
- The ECM flashes the MIL and sets a DTC when either one of the following conditions, which could cause the three-way catalytic converter
damage, is detected (2 trip detection logic).
- In every 200 crankshaft revolutions at a high engine speed, the threshold misfiring percentage is recorded once.
- In every 200 crankshaft revolutions at a normal engine speed, the threshold misfiring percentage is recorded 3 times.
Misfire Monitor for Mexico Models
The ECM illuminates the MIL and sets a DTC when either one of the following conditions, which could cause emission deterioration, is detected (2
trip detection logic).
- Within the first 1000 crankshaft revolutions of the engine starting, an excessive misfiring rate (approximately 1000 misfires per 1000
crankshaft revolutions) occurs once.
- An excessive misfiring rate (approximately 500 misfires per 1000 crankshaft revolutions) occurs a total of 4 times.
The ECM flashes the MIL and sets a DTC when the following condition, which could cause the three-way catalytic converter damage, is detected (2
trip detection logic).
- A catalyst damage misfire, which is monitored every 200 crankshaft revolutions, occurs 3 times.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS