HINT
If the connectors are not connected securely, reconnect the connectors and proceed to the next inspection.
(d) Disconnect the connectors from the side airbag sensor RH and rear airbag sensor RH.
(e) Check that the terminals of connectors are not damaged.
OK:
The terminals are not deformed or damaged.
NG -- REPLACE FLOOR WIRE
OK -- Continue to next step.
15. CHECK FLOOR WIRE (OPEN)
(a) Using SST, connect terminals 2 (BCR+) and 1 (BCR-) of connector C.
NOTICE:
Do not forcibly insert SST into the terminals of the connector when connecting.
SST : 09843-18040
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- REPLACE FLOOR WIRE
OK -- Continue to next step.
16. CHECK FLOOR WIRE (SHORT)
(a) Disconnect SST from connector C.
(b) Measure the resistance according to the value(s) in the table below.
No comments: