(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- REPLACE A/C COMPRESSOR (SOLENOID VALVE) See: Heating and Air Conditioning/Compressor HVAC/Service
and Repair/Removal and Replacement/Removal
OK -- Continue to next step.
2. CHECK HARNESS AND CONNECTOR (A/C COMPRESSOR (SOLENOID VALVE) - BODY GROUND)
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.
3. CHECK HARNESS AND CONNECTOR (A/C COMPRESSOR (SOLENOID VALVE) - A/C AMPLIFIER)
(a) Disconnect the A/C amplifier connector.
No comments: