The display is as specified in the Normal Condition column.
Result:
C -- REPLACE A/C AMPLIFIER
B -- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE See: Heating and Air
Conditioning/Testing and Inspection/Symptom Related Diagnostic Procedures
A -- Continue to next step.
2. INSPECT AMBIENT TEMPERATURE SENSOR
(a) Remove the ambient temperature sensor.
(b) Disconnect the ambient temperature sensor connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NOTICE:
* Hold the sensor only by its connector. Touching the sensor may change the resistance value.
* When measuring, the sensor temperature must be the same as the ambient temperature.
HINT
As the temperature increases, the resistance decreases (see the graph).