Thursday, March 19, 2020

2010 Lexus Truck RX 350 AWD V6-3.5L (2GR-FE) P Code Charts Page 1727


2. PURGE FLOW MONITOR



The purge flow monitor consists of the 2 step monitors. The 1st monitor is conducted every time and the 2nd monitor is activated if necessary.



- The 1st monitor



- While the engine is running and the purge VSV is on (open), the ECM monitors the purge flow by measuring the EVAP pressure change.



If negative pressure is not created, the ECM begins the 2nd monitor.



- The 2nd monitor



- The vent valve is turned on (closed) and the EVAP pressure is then measured. If the variation in the pressure is less than 0.15 kPa (1.13



mmHg), the ECM interprets this as the purge VSV being stuck closed, and illuminates the MIL and sets DTC P0441 (2 trip detection



logic).



Atmospheric pressure check:



In order to ensure reliable malfunction detection, the variation between the atmospheric pressures, before and after conduction of the purge



flow monitor, is measured by the ECM.



MONITOR STRATEGY



TYPICAL ENABLING CONDITIONS

No comments:

Post a Comment