Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- REPLACE NO. 2 FLOOR WIRE
OK -- Continue to next step.
12. CHECK WIRE HARNESS (OPEN)
(a) Connect the connectors that link the No. 2 floor wire and front door wire LH.
(b) Using SST, connect terminals 2 (BDL+) and 1 (BDL-) of connector E.
NOTICE:
Do not forcibly insert SST into the terminals of the connector when connecting.
SST : 09843-18040
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- CHECK FRONT DOOR WIRE LH (OPEN)
OK -- Continue to next step.
13. CHECK WIRE HARNESS (SHORT)
(a) Disconnect SST from connector E.
No comments:
Post a Comment