WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. READ VALUE USING TECHSTREAM
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Check the value(s) by referring to the table below.
Air Conditioner
OK:
The display is as specified in the Normal Condition column.
Result:
C -- REPLACE A/C AMPLIFIER
B -- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE See: Heating and Air
Conditioning/Testing and Inspection/Symptom Related Diagnostic Procedures
A -- Continue to next step.
2. INSPECT EVAPORATOR TEMPERATURE SENSOR
(a) Remove the evaporator temperature sensor.
(b) Disconnect the evaporator temperature sensor connector.