INSPECTION PROCEDURE
NOTICE:
* When the power management control ECU is replaced with a new one and the cable from the negative (-) battery terminal is
connected, the power source mode becomes the on (IG) mode. When the battery is removed and reinstalled, the power source
mode that was selected when the battery was removed is restored.
* Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
1. CHECK HARNESS AND CONNECTOR (BATTERY - POWER MANAGEMENT CONTROL ECU) See: B2271
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY - POWER MANAGEMENT CONTROL ECU)
OK -- Continue to next step.
2. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND) See: B2271
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY
GROUND)
OK -- Continue to next step.
3. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
(a) Remove the instrument panel junction block assembly See: Body and Frame/Body Control Systems/Body Control Module/Service
and Repair/Removal.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
OK -- Continue to next step.
4. CHECK HARNESS AND CONNECTOR
(a) Measure the resistance according to the value(s) in the table below.